Maquinaria y plantas industriales usadas

A continuación, se muestra una lista de las instalaciones usadas, con su ficha técnica. Le invitamos a consultar las fichas individuales y, si está interesado, a ponerse en contacto con nosotros. Gracias

Regenerative thermal oxydizer – REF. 90-26

PLANT TYPE:Regenerative thermal oxidizer
MAX AIR FLOW (Nm³/h):30.000
INSTALLED ELECTRIC POWER (kW):80
GAS BURNER CAPACITY (kW):750
AVAILABILITY:available
DIMENSIONS (m):16 x 7 x 7 (h)
STACK HEIGHT (m):13,15
YEAR:2018

Regenerative thermal oxydizer – REF. 89-26

PLANT TYPE:Regenerative thermal oxydizer
MAX AIR FLOW Nm³/h: 25.000
INSTALLED ELECTRIC POWER (kW):80
GAS BURNER CAPACITY (kW):600
AVAILABILITY:available
DIMENSIONS (m): 20,5 x 5 x 7 (h)
STACK HEIGHT (m):12,7
YEAR:2019

Regenerative thermal oxidizer – REF. 88-26

PLANT TYPE:Regenerative thermal oxidizer
MAX AIR FLOW (Nm³/h):10.000
INSTALLED ELECTRIC POWER (kW):38,5
GAS BURNER CAPACITY (kW):300
AVAILABILITY:Available from January 2027
DIMENSIONS (m):11 x 4 x 4 (h)
STACK HEIGHT (m):11,1
YEAR:2023

Regenerative thermal oxidizer – REF. 87-26

PLANT TYPE:Regenerative thermal oxidizer
MAX AIR FLOW (Nm³/h):40.000
INSTALLED ELECTRIC POWER (kW):139,5
GAS BURNER CAPACITY (kW):1.000
AVAILABILITY:Available
DIMENSIONS (m):20 x 6,5 x 7 (h)
STACK HEIGHT (m):18
YEAR:2008

Regenerative thermal oxidizer – REF. 86-26

PLANT TYPE:Regenerative thermal oxidizer
MAX AIR FLOW (Nm³/h):9.000
INSTALLED ELECTRIC POWER (kW):31
GAS BURNER CAPACITY (kW):300
ADDITIONAL FUEL:Natural gas
AVAILABILITY:Available
DIMENSIONS (m):9,6 x 2,5 x 3,7 (h)
STACK HEIGHT (m):8
YEAR:2021

Regenerative thermal oxidizer – REF. 84-26

PLANT TYPE: Regenerative thermal oxidizer
MAX AIR FLOW (Nm³/h):10.000
INSTALLED ELECTRIC POWER (kW):40
GAS BURNER CAPACITY (kW):300
ADDITIONAL FUEL:Natural gas
AVAILABILITY:Available
DIMENSIONS (m):11,7 x 3,5 x 6,8 (h)
STACK HEIGHT (m):14
YEAR:2016

Regenerative thermal oxydizer – REF. 83-26

PLANT TYPE:Regenertative thermal oxydizer
MAX AIR FLOW (Nm³/h):8.000
INSTALLED ELECTRIC POWER (kW):21
GAS BURNER CAPACITY(kW):233
ADDITIONAL FUEL:Natural gas
AVAILABILITY:Available
DIMENSIONS (m):10 x 3 x 4,5 (h)
STACK HEIGHT (m):10
YEAR:2016

Brofind’s used regenerative thermal oxidizer (RTO) has been professionally inspected and verified by our technical team to ensure reliable operation and high performance. It represents a cost-effective solution for companies looking to reduce VOC emissions while significantly lowering the initial investment compared to purchasing a new plant.

Designed for industrial air pollution control, this regenerative thermal oxidizer combines high destruction efficiency with excellent thermal energy recovery, helping reduce operating costs and fuel consumption. Immediate availability also allows shorter delivery times and faster installation, minimizing production downtime.

Main benefits

  • Brofind inspected and technically verified equipment
  • Immediate availability from stock
  • Lower investment than a new regenerative thermal oxidizer
  • High VOC abatement efficiency
  • Excellent thermal energy recovery for reduced operating costs
  • Suitable for integration into existing industrial production lines
pide info

Rotor concentrator – REF. 82-25

PLANT TYPE:Rotor concentrator
MAX AIR FLOW (Nm³/h):30.000
DIMENSIONS:1.730mm
AVAILABILITY:Available

Activated carbon filtration unit – REF. 71-23

PLANT TYPE:Activated carbon filtration unit
MAX AIR FLOW (Nm³/h):5.000
INSTALLED ELECTRIC POWER (kW):45
AVAILABILITY:Available
CONSTRUCTION YEAR:2022
DIMENSIONS (m):10 x 5,5 x 4
STACK HEIGHT (m):8

Regenerative thermal oxydizer – REF. 69-23

PLANT TYPE:Regenertative thermal oxydizer
MAX AIR FLOW (Nm³/h):10.000
INSTALLED ELECTRIC POWER (kW):35
GAS BURNER CAPACITY (kW):400
ADDITIONAL FUEL:natural gas
AVAILABILITY:currently available
DIMENSIONS (m):11 X 3 X h 3,8
STACK HEIGHT (m):10
YEAR:2017

Aquellos que de cualquier manera utilicen el/los producto/s son los únicos responsables de determinar (a) la idoneidad del producto para el uso previsto, (b) la forma adecuada de procesamiento y mantenimiento del producto para garantizar la seguridad y la calidad y (c) los efectos químicos, físicos y sobre la salud relacionados con dichas actividades, (d) informarse para poder decidir si se necesitan datos específicos para el uso previsto en relación con las normas y reglamentos vigentes en el lugar de uso previsto. Los datos de rendimiento proporcionados en este documento se ofrecen como guía para que el usuario determine la idoneidad. Las dimensiones y pesos son nominales y no se pueden utilizar para la producción, incluso cuando se indican las tolerancias. Lea y comprenda este documento antes de comprar el producto. Póngase en contacto con su representante de Brofind Spa si tiene alguna pregunta o comentario. A menos que se mencione específicamente en el documento, todos los datos, en caso de que se implique o se requiera un concepto de factor de seguridad o parámetro de seguridad a tener en cuenta, se expresan sin él. Los clientes, instaladores y terceros son los únicos responsables de los daños o el incumplimiento de las prestaciones derivados de un uso inadecuado, abuso, negligencia o manipulación, transporte o almacenamiento inadecuados.